First, the pneumatic diaphragm pump troubleshooting steps:

1. Prior to removing the pneumatic diaphragm pump, mark the gas chambers and liquid chambers on the left and right sides respectively to facilitate subsequent reassembly.

2. Use a wrench to loosen the small clamp connecting the outlet tube to the liquid chamber. Remove the outlet tube to see the ball and valve seat. Remove the ball and seat and check for other wear and tear on the pump. Chemical corrosion, cracks and the like.

3. Use a wrench to loosen the small clamp connecting the inlet tube to the liquid chamber. Remove the outlet tube to see the ball and valve seat. Remove the ball and seat and check for other wear and tear, chemical corrosion, and cracks on the pump.

4. Use a wrench to separate the liquid chamber from the pump intermediate. Remove the liquid chamber to see the diaphragm and diaphragm clamp.

5. Use tools or wrenches to fix the left and right edges of the diaphragm clamp to separate the diaphragm assembly from the intermediate body. Then turn clockwise to loosen the diaphragm assembly. After removing the diaphragm from the clamp, remove the shaft from the intermediate body.

6. Use a clamp (padded wood) to separate the shaft from the diaphragm unit and check shaft, clamp, diaphragm for damage and corrosion.

7. Install from step 6 to step 1

Second, pneumatic, electric diaphragm pump fault performance and inspection methods

Fault (1): Pneumatic diaphragm pump action, but the flow is small or no liquid out:

Processing: 1. Check the cavitation of the pump to reduce the speed of the pump to allow liquid to enter the chamber.

2. Check if the valve ball is stuck. If the operating fluid is incompatible with the pump elastomer, the elastomer will swell. Please replace the appropriate material elastomer.

3. Check the pump inlet connector is completely tight leak, especially near the entrance of the valve ball to be locked.

Fault (2): Diaphragm Pump Air Valve Icing:

Treatment: Check the compressed air moisture content is too high, the installation of air-drying equipment

Fault (3): diaphragm pump outlet bubble generation:

Treatment: Check the diaphragm rupture, check the clamp is locked, especially the inlet pipe clamp.

Fault (4): the product flows out from the air outlet:

Treatment: check whether the diaphragm rupture, check the diaphragm and the clamp inside and outside the clamp on the shaft

Fault (5): valve rattling: increase exports or import head.

Fault (6): Pneumatic, electric diaphragm pump does not move or slow operation:

Processing: 1. Check the air inlet filter or air filter device for impurities.

2. Check if the air valve is stuck and clean the air valve with cleaning fluid.

3. Check air valve for wear and tear, replace new parts if necessary.

4. Check the center of the seal parts condition, if severely worn, you can not achieve the sealing effect, and the air will be discharged from the air outlet. Due to its special construction, use only GLYD circles.

5. Check the air valve piston activity is normal.

6. Check the type of lubricant. If the added lubricant is above the recommended viscosity, the piston may get stuck or malfunction. Recommend the use of thin and antifreeze lubricants. (ISO grade 15 / 5WT antifreeze oil)

Third, the pump removal and reassembly guide:

WARNING: Before working on the pump, first remove the air source tubing from the pump and vent the air pressure in the pump. Remove all tubing that connects to the pump inlet and outlet, and drain fluid from the pump into a suitable container. Wear protective cap, glasses, gloves.

Auto Iridium/Platinum Spark Plug

Our company was set up in 2002.We are using the advanced cold punch technology to produce spark plug which is similar to NGK and Champion technology.With such technology, the metal shell and ceramic are better protected the quality of the spark plug are more stable to get avoid from air leaking and broken.Our spark plug products are ranged into more than 100 models with an anual out put of 6 million pcs. Besides the advanced technology,we also have a strong advantage of automatical production.Most of our production device is automatical that we have very high,efficiency and stable quality.Throughout such years of developing,we have gained a good reputation at domestic motorcycle manufacturer.Furthermore,our products have been exported to South East Asia, Middle East, Australia and so on. Revolution,refine and devotion are our principal of working.Welcome to visit us and raise your demand and your comments request are our target to strive.