The UHZ magnetic flap level gauge is a device specially developed for liquid level measurement based on the principle of magnetic principle, Archimedes (buoyancy law) and other subtle combination of mechanical transmission characteristics; UHZ type is the most basic One product, the rest of the products are based on the extension; we give them more practical functions while detecting the liquid level.
UHZ magnetic flap level gauge has flameproof and intrinsic safety protection performance. The whole process measurement has no blind zone, the display is eye-catching, the reading is intuitive, and the measurement range is large. In particular, the on-site indication part, because it is not in direct contact with the liquid medium, is superior to high temperature, high pressure, high viscosity, toxic and harmful, and highly corrosive medium. The UHZ magnetic flap level gauge is made of wear-resistant material and therefore has corrosion resistance. Therefore, compared with the traditional glass tube, the magnetic flap level gauge has higher reliability, safety, advancement and practicability. It can be widely used in liquid level measurement and control in the production process of electric power, petroleum, chemical metallurgy and environmental protection, shipbuilding, construction, food and other industries.
UHZ magnetic flap level gauge routine maintenance:
1. The magnetically permeable material is not allowed to approach around the body, and the wire is fixed. Otherwise, it will affect the normal operation of the magnetic flap level gauge;
2. When commissioning, first open the upper pilot valve, then slowly open the lower valve to allow the medium to smoothly enter the main conduit (the medium should avoid the rapid impact of the float during operation, causing the float to fluctuate and affect the display accuracy). Observe the magnetic red and white ball. Whether the flipping is normal, then close the lower pilot valve, open the drain valve, and let the liquid level in the main conduit drop. According to this method, it is normal, and it can be put into operation (except for special liquids such as corrosive);
3. The medium should not contain solid impurities or magnetic substances to avoid jamming the float;
4. UHZ magnetic flap level gauge should be cleaned according to the medium condition, and the main conduit should be cleaned regularly. 5. Before use, the small ball below zero should be set to red with the correct magnetic steel, and the other balls should be set to white;
6. The installation position of the magnetic flap level gauge should be avoided or away from the inlet and outlet of the material medium to avoid rapid changes in the local area of ​​the material fluid and affect the accuracy of the liquid level measurement;
UHZ magnetic flap level gauge appears in red and white. There are generally two kinds of conditions. One is due to transportation or on-site movement, causing the column to change, and the second is because the magnetic column, the float, the high temperature or the use time is too long. , causing loss of magnetism. If it is the first case, take a magnet or a magnetic float and go it all the way from the beginning to the end. If it is the second case, it is time to replace the panel or float.
The UHZ magnetic flap level gauge can be used for medium level detection in a variety of towers, tanks, tanks, ball vessels and boilers. This series of level gauges can be highly sealed, leak proof and suitable for high temperature, high pressure and corrosion resistant applications. It compensates for the defects such as poor definition and easy cracking of the glass plate (tube) level gauge, and the whole process measurement has no blind zone, and the display is clear and the measurement range is large.